By the Evochem technical team. Reviewed 18 November 2026. Review this article every six months. Product selection and dilution must follow the current product label, equipment requirements and your plant's validated cleaning procedure.
Three levers usually do the most to cut chemical and water use in a dairy CIP system: keeping the detergent concentration accurate, tuning the cycle times to the soil, and getting the pre-rinse right. They can often be improved without changing equipment, but every change must first be checked against your validated cleaning cycle and your hygiene results.
This article goes deeper than our guide to CIP vs OPC cleaning. That guide helps you choose a method. This one helps you get more from a CIP system once you have it.
Concentration accuracy: Use the detergent strength the soil needs, no more and no less.
Cycle-time tuning: Run each step as long as the soil needs, and check it with data.
Pre-rinse optimization: Remove as much milk and soil as you can before the detergent step.
Milk leaves two kinds of soil behind. Fat and protein form a film on every surface the milk touches. On heated surfaces, such as pasteuriser plates, calcium and protein can bake on as milkstone. A CIP programme has to remove both, every cycle, before a sanitiser can work.
A typical dairy CIP cycle has these steps: pre-rinse, alkaline wash, intermediate rinse, an acid step where milkstone or scale builds up, a final rinse, and sanitising. You can read the full sequence on our dairy processing page.
Waste usually comes from four places: detergent dosed stronger than the soil needs, which also needs more rinse water to clear; steps that run longer than the soil needs because settings have not been reviewed; a weak pre-rinse that leaves most milk soil for the detergent; and rinse steps that run on a fixed timer instead of an end-point.
Cutting any of these without data can make cleaning worse. That is why the first step is measurement.
You cannot improve what you do not measure. Before you change anything, record one normal week of CIP data for each circuit.
| What to record | How | Why it matters |
|---|---|---|
| Detergent concentration | Conductivity reading, checked by titration at set intervals | Shows over-dosing and under-dosing |
| Detergent and water used per cycle | Flow meter or tank levels | Gives your chemical and water baseline |
| Temperature of each step | Probe at the return line | Cold or hot solutions change the time you need |
| Time of each step | Controller log or stopwatch | Shows where time can be reviewed |
| Rinse end-point | Conductivity or turbidity of the return water | Shows when a rinse is really finished |
| Hygiene result | Visual check and your normal swab or ATP result | Proves that cleaning has not got worse |
| Volume processed between cycles | Production records | Lets you compare use per cycle or per litre of milk |
Detergent strength is the easiest place to lose control. Too strong, and you pay for chemical you do not need and use more rinse water to remove it. Too weak, and soil is left behind, so the circuit has to be cleaned again.
Check the strength of the wash solution by conductivity and confirm it by titration at set intervals. Calibrate dosing pumps and meters on a schedule. A drifting pump is a common cause of over-dosing. Watch for dilution of the wash tank by water left in the line, which lowers strength. Match the dilution to the soil: heavily soiled circuits and lightly soiled ones need not run the same setting. Keep the dilution within the label range for the product and your validated cycle.
For example, our Clastox 50 and Clastox Plus have a published dilution range of 0.5% to 5% depending on the soil. Our technical team can help you pick a starting point for each circuit.
Clastox 50High Performance Alkaline DetergentPotent alkaline liquid detergent specially engineered for heavy-duty cleaning. Provides exceptional scale prevention and hard water resistance while effectively penetrating into stubborn soils, animal fats, and milk residues.
Clastox PlusLow Foaming Heavy Duty Alkaline DetergentPotent alkaline liquid detergent specially engineered to meet the rigorous demands of food processing plants. Its advanced detergent systems not only penetrate deeply into stubborn soils, animal fats, and milk residues, but also provide exceptional scale prevention and hard water resistance, ensuring that your cleaning operation runs smoothly and efficiently. Designed for heavy-duty applications.Cleaning depends on four things working together: chemical, temperature, time and flow. If you raise one, you can sometimes lower another. Time is the one most often left unreviewed.
Review how long each step runs against the baseline data. Look at steps that run on a fixed timer. Use end-points where you can. For example, end a rinse when the return water conductivity or turbidity reaches the level you set, instead of after a fixed time.
Check flow. Low flow in a line or a blocked spray ball reduces cleaning, and no extra time will fully fix that. Check that temperature reaches the set value at the return line, not only at the heater. Shorten a step only in small trials, and only if your hygiene results hold.
The pre-rinse pushes out residual milk before the detergent step. A better pre-rinse means the detergent has less to do, and the wash solution stays cleaner for longer.
Run the pre-rinse until the return water is nearly clear. Use turbidity or visual checks. Do not run it far past that point, because extra water removes little more. Use enough flow to push milk out of the line. Low flow leaves film behind.
Where your plant design and your QA team allow it, final-rinse water can sometimes be reused as the next pre-rinse. Check this with QA first. Recover milk from the line before the pre-rinse, so less product goes to drain.
Water hardness. In hard-water areas, scale builds up and the circuit needs more cleaning. Clastox 50 and Clastox Plus are formulated with scale prevention and hard-water resistance.
Equipment condition. Worn spray balls, dead legs and gaskets leave soil, which makes the whole cycle work harder.
The acid step. Run it where milkstone or scale builds up, not on every cycle by habit. Evochem does not make an acid CIP detergent. Ask our technical team for the right product for your circuit and water.
Sanitising. Sanitising is a separate step on a cleaned and rinsed surface. Peracetic acid sanitisers such as Sanix Peraxy are commonly used after CIP.
Clastox 50High Performance Alkaline DetergentPotent alkaline liquid detergent specially engineered for heavy-duty cleaning. Provides exceptional scale prevention and hard water resistance while effectively penetrating into stubborn soils, animal fats, and milk residues.
Clastox PlusLow Foaming Heavy Duty Alkaline DetergentPotent alkaline liquid detergent specially engineered to meet the rigorous demands of food processing plants. Its advanced detergent systems not only penetrate deeply into stubborn soils, animal fats, and milk residues, but also provide exceptional scale prevention and hard water resistance, ensuring that your cleaning operation runs smoothly and efficiently. Designed for heavy-duty applications.
Sanix PeraxyPeracetic Acid Based SanitizerClear liquid oxidizing sanitizer for the food industry, formulated with peracetic acid, hydrogen peroxide, and acetic acid. Eliminates a broad spectrum of microorganisms, including bacteria, spores, and viruses, ensuring high-level sanitation for pre-cleaned surfaces.Look at the whole cycle. A change that saves chemical but needs two extra rinses may cost you more.
| If you change this | It may do this | Check this |
|---|---|---|
| Raise detergent strength | Cleans harder, but needs more rinse water to clear | Rinse end-point and residue |
| Lower detergent strength | Saves chemical, but may leave soil | Hygiene result and repeat cleans |
| Lengthen the wash | More contact, but more energy and downtime | Whether a stronger solution is cheaper |
| Improve the pre-rinse | Less soil reaches the wash, so the wash stays cleaner | Pre-rinse water use |
| End rinses on an end-point | Avoids both short and over-long rinses | Sensor accuracy and calibration |
Pick one circuit and set the baseline for it.
Agree the change with your QA team and follow your change-control procedure.
Change one setting only, such as one step time or one dilution.
Run the changed cycle and record the same data as the baseline.
Check hygiene results after every changed cycle.
If results hold, repeat over a longer period before you make the change permanent.
If results get worse, go back to the validated setting and find the cause.
Record the change, the data and the sign-off.
Evochem manufactures dairy cleaning chemicals in Bengaluru for milk chilling centres, processing plants and milk-product units. Our alkaline CIP detergents for recirculating circuits are below. Dilutions are as published on the product pages. See our dairy cleaning chemicals page for the full range, or the dairy CIP cleaning programme case study.
These products do not reduce chemical or water use on their own. Accurate dosing, tuned cycle times and a good pre-rinse do that. What our team can do is help you choose a product and dilution for each circuit.
To get advice, send us the list of CIP circuits and soils on each; your water hardness; how you dose and heat the CIP solutions today; and any soft metals or gaskets in the circuit that need care.
For the method choice, read CIP vs OPC cleaning. For the range, see CIP cleaning chemicals.
| Product | Type | Where it is used | Published dilution |
|---|---|---|---|
| Clastox 50 | High-performance alkaline detergent | CIP circuits and soak tanks, including milk residues | 0.5% to 5% |
| Clastox Plus | Low-foaming heavy-duty alkaline detergent | CIP circuits and soak tanks, including milk residues | 0.5% to 5% |
| Sanix Peraxy | Peracetic acid based sanitiser | Sanitising a cleaned and rinsed circuit | As on the label |
Clastox 50High Performance Alkaline DetergentPotent alkaline liquid detergent specially engineered for heavy-duty cleaning. Provides exceptional scale prevention and hard water resistance while effectively penetrating into stubborn soils, animal fats, and milk residues.
Clastox PlusLow Foaming Heavy Duty Alkaline DetergentPotent alkaline liquid detergent specially engineered to meet the rigorous demands of food processing plants. Its advanced detergent systems not only penetrate deeply into stubborn soils, animal fats, and milk residues, but also provide exceptional scale prevention and hard water resistance, ensuring that your cleaning operation runs smoothly and efficiently. Designed for heavy-duty applications.
Sanix PeraxyPeracetic Acid Based SanitizerClear liquid oxidizing sanitizer for the food industry, formulated with peracetic acid, hydrogen peroxide, and acetic acid. Eliminates a broad spectrum of microorganisms, including bacteria, spores, and viruses, ensuring high-level sanitation for pre-cleaned surfaces.Disclaimer: This article is general information. Always follow the product label, the MSDS and your plant's own validated cleaning and food safety procedures. Changes to a validated cleaning cycle should go through your plant's change control. What suits your plant depends on your equipment, soils, water and regulator. Evochem is a brand of Ennwin Industries Private Limited.
It varies by plant, so we do not publish a figure. Savings come from using less chemical through accurate dosing, shortening steps that run longer than the soil needs, and using less rinse water. Set a baseline first. Then you can measure your own result, instead of relying on a number from another plant.
Record, for each CIP circuit and cycle: the litres of detergent and water used, the detergent concentration, the temperature, the time of each step and the result of your hygiene check. Divide by something meaningful for your plant, such as each cycle or each litre of milk processed. Compare before and after each change.
Often yes, because the main levers are settings and control, not new equipment. Whether a given product and dilution suit your skid depends on the dosing method, the materials in the circuit, your water and your soil. Share these details with our technical team and we will advise.
Yes. A stronger solution or a longer wash may need more rinse water to clear. A better pre-rinse removes more soil before the wash, so the detergent has less to do. Look at the whole cycle together, not one step. Never cut a step below what your validated cycle and the product label require.
Common tools are a conductivity sensor for solution strength and rinse end-points, a flow meter, a temperature probe, a turbidity sensor for the pre-rinse, and a titration kit to check the concentration by hand. A simple log of each cycle is useful even without automation.
It can. A validated cleaning cycle should only be changed through your plant's own change-control and validation process, with your QA team involved. Check what your food safety regulator and your customers' audits require. Optimization must never come at the cost of hygiene results.